Danfoss P30 User Manual

Browse online or download User Manual for Unknown Danfoss P30. ECL Comfort 200

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Data sheet
ECL Comfort 200
230 V a.c. and 24 V a.c.
1
VD.7B.A6.02 © Danfoss 11/2008
DH-SMT/DK
Application The ECL Comfort 200 electronic controller is pre-
programmed for a variety of different applica-
tions. Each application has its own card
describing the settings in different languages.
The ECL Comfort 200 controller has triac outputs
for motorized valve control and 2 relay outputs
for pump/valve control.
It is possible to connect up to 4 Pt 1000
temperature sensors and communication
modules.
The enclosure is designed for wall and panel
mounting as well as for mounting on a DIN rail.
ECL Comfort 200 communicates by means of the
module ECA 71 via MODBUS to SCADA* systems.
* Supervisory Control And Data Acquisition
ECL Cards and applications
The ECL Comfort 200 controller is pre-pro-
grammed for different applications.
Each application has its own ECL Card with an
overview of the end-user and installer settings.
Following applications can be realized together with ECL Comfort 200:
Card Code no.
(English version)
Application type description Controller outputs
(without accessories)
P16 087B4663 Constant temperature control of hot-water circuits with flow system or
storage tank with built-in heating coil
1 x 3-point, 1 × 2-point
P17 087B4664 Constant temperature control of hot-water circuits with storage
charging system
1 × 3-point, 2 × 2-point
P20 087B4660 Weather compensated flow temperature control of boiler systems 2 × 2-point
P30 087B4653 Weather compensated flow temperature control of heating systems
with fixed return temperature limitation
1 × 3-point, 1 × 2-point
Each of the abovementioned code nos. comprises one ECL Card, one manual and one quick guide.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - ECL Comfort 200

Data sheetECL Comfort 200230 V a.c. and 24 V a.c.1VD.7B.A6.02 © Danfoss 11/2008DH-SMT/DKApplication The ECL Comfort 200 electronic controller is pre

Page 2 - Data sheet ECL Comfort 200

Data sheet ECL Comfort 2002VD.7B.A6.02 © Danfoss 11/2008DH-SMT/DKOrderingController and enclosure:Type Designation Code no.ECL Comfort 200 Universa

Page 3

Data sheet ECL Comfort 2003VD.7B.A6.02 © Danfoss 11/2008DH-SMT/DKP30: Typical heating system (central heating)P16: Typical DHW systemP17: Typical D

Page 4

Data sheet ECL Comfort 2004VD.7B.A6.02 © Danfoss 11/2008DH-SMT/DKOperationArrow buttons. Switch between the lines of the ECL Card.Shift button. Sw

Page 5

Data sheet ECL Comfort 2005VD.7B.A6.02 © Danfoss 11/2008DH-SMT/DKWiring - 230 V a.c.Supply voltage 230 V a.c. - 50 HzVoltage range 207 to 244 V a.c

Page 6

Data sheet ECL Comfort 2006VD.7B.A6.02 © Danfoss 11/2008DH-SMT/DKDimensionsCut-out for mounting Mounting in a panel (connector set, code no. 0 87B1

Page 7

Data sheet ECL Comfort 2007VD.7B.A6.02 © Danfoss 11/2008DH-SMT/DK

Page 8

Data sheet ECL Comfort 2008VD.7B.A6.02Produced by Danfoss A/S © 11/2008

Comments to this Manuals