5. Electrical connections are simpli ed by using a Wiring
Centre. However, if this is not used, the wallplate terminal
identi cation is as shown.
If the system being controlled is 230Vac then terminals
3 and L must be linked with insulated cable capable
of carrying full load current. Whilst the unit does not
require an earth connection, a terminal is provided on the
wallplate for earth continuity purposes.
6. Referring to the wiring diagrams on page 6-9, connect the
unit as shown.
7. Find out from the user whether the unit is required to
operate in 7-day mode (factory preset) or weekday/
weekend mode (5/2 day). To convert to 5/2 day mode
remove the small two-way connector from the pins
towards the left of the recess on the rear of the module,
then press the button marked R/S under the  ap to RESET
the unit.
8. Ensure all dust and debris are cleared from the area. Plug
the module into the wallplate by locating it onto the
wallplate and, when  ush with it, sliding it down, ensure
the hook at the top of the wallplate engages with the slot
at the back of the module.
9. Before setting the programme, check the unit and circuit. Set
the rocker switch to WATER & HEATING. Press the SELECT
button until the bar in the display lines up with the word ON.
Adjust the remote thermostats to check the system operates
correctly.
Installation
Water Heating
COM
Mains Supply
(via 3 amp fuse)
ON ON
NL
123 5 6