Danfoss FC 100 Series Operations Instructions

Browse online or download Operations Instructions for Networking Danfoss FC 100 Series. Danfoss FC 100 Series Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Contents
1 Copyright
3
Copyright 3
Copyright, Limitation of Liability and Revision Rights 3
2 Safety
5
Safety 5
3 Introduction
7
Introduction 7
4 How to install
11
How to install 11
5 Configuration of the system
19
Configuring the System 19
Network Variable Description 22
VSD 6010 Profile 34
Network Variable Description - VSD Profile - input 35
Network Variable Description - VSD Profile - Output 36
Network Variable Description - VSD Profile - Configuration 37
Node Object 39
Network Timer Functions 40
6 How to control the Frequency Converter
41
How to Control the FC 100 41
Open Loop 41
Closed Loop 41
Danfoss FC Control Profile 42
7 How to access FC 100 parameters
45
User-defined Network Variables UNVT 45
8 Parameters
49
Parameter list 49
Parameter Group 8-** 49
Parameter Group 11 54
Data Types Supported by FC 100 55
9 Troubleshooting
57
Alarm-, Warning and Extended Status Word 57
Alarm words 58
Warning words 59
Extended Status Word 60
VLT® FC 100 LonWorks Contents
MG.11.E2.02 - VLT
®
is a registered Danfoss trademark
1
Page view 0
1 2 3 4 5 6 ... 65 66

Summary of Contents

Page 1 - VLT® FC 100 LonWorks Contents

Contents1 Copyright3Copyright 3Copyright, Limitation of Liability and Revision Rights 32 Safety5Safety 53 Introduction7Introduction 74 How to install1

Page 2 - Contents VLT® FC 100 LonWorks

4 How to install VLT® FC 100 LonWorks10MG.11.E2.02 - VLT® is a registered Danfoss trademark4

Page 3 - 1Copyright

4How to install4.1 How to install4.1.1 The LonWorks OptionThe LonWorks option is equipped with two termination switches, S300 and S301, enabling doubl

Page 4 - 2 Safety VLT® FC 100 LonWorks

4.1.3 Network TerminationDependent on the type of topology, at least one of the connected nodes must be terminated (52.5Ω). The option has two built-

Page 5 - 2.1 Safety

4.1.4 Connecting the Bus LineConnect bus wire NET A to terminal 79 and NET B to 80 of the terminal connector.Terminal Connection79 NET A*80 NET B*61

Page 6

4.1.7 EMC PrecautionsThe following EMC precautions are recommended in order to achieve interference-free operation of the LonWorks network. Additional

Page 7 - 3Introduction

4.1.8 LED BehaviourMS: Service LED (red)Situation LED DescriptionConfigured state (Nornal operation) ½ sec. ON, then continously OFF The node is confi

Page 8

4.1.9 How to Install Option in Frequency ConverterItems required to install a fieldbus option in the frequency converter:- The fieldbus option- Fieldb

Page 9 - 3.1.8 Abbreviations

Instructions:- Remove LCP panel from the FC 100- Remove the frame located beneath and discard- Push the option into place. Two positions are possible,

Page 10 - MG.11.E2.02 - VLT

5 Configuration of the system VLT® FC 100 LonWorks18MG.11.E2.02 - VLT® is a registered Danfoss trademark5

Page 11 - 4How to install

5 Configuration of the system5.1 Configuring the System5.1.1 How to Configure the LonWorks NetworkThe LonWorks option card contains a Neuron chip with

Page 12 - 4.1.3 Network Termination

Extended status words 60Reference Scaling - Examples 61Network Variables - Overview 62Index64Contents VLT® FC 100 LonWorks2MG.11.E2.02 - VLT® is a reg

Page 13

5.1.3 FC VSD ProfileThe FC VSD Profile describes all Danfoss VLT specific network variables.Input variablesVariable Function Variable Name SNVT type P

Page 14 - 4.1.7 EMC Precautions

Output variablesVariable function Variable name SNVT type Profile FC 100 par.Status word nvoStatusword SNVT_state FC VSD 16-03Drive output [%] nvoOutp

Page 15 - 4.1.8 LED Behaviour

5.2 Network Variable Description5.2.1 - FC VSD Profile - inputStart/StopVariablename:SNVTtype:State: Value: Command:nviStartStop SNVT_switch 0 (False)

Page 16 - 130BT247.12

Reference [%]Variablename:SNVTtype: Value: nviRefPcnt SNVT_lev_percent Min. Max. Resolution: -163.840 % +163.830 % 0.005 %This variable sends the

Page 17

Digital / Relay OutputsVariablename:SNVTtype:State:nviDigitOutput SNVT_state_64 Boolean 1 bit x 64This variable controls the state of the digital outp

Page 18

Analog Output (X30 / 8)Variablename:SNVTtype: Value: nvi101AnOut1 SNVT_lev_percent Min.: Max.: Resulution: 0 % 100 % 0.01 %NB!This output variabl

Page 19 - 5 Configuration of the system

These variables contain the value allocated to the analog output terminal X42/7-11 of the Analog I/O option. The variable type is changeable with thec

Page 20 - 5.1.3 FC VSD Profile

5.2.2 Network variable description - FC VSD Profile - outputStatus WordVariable name: SNVT type: State:nvoStatusWord SNVT_state Boolean 1 bit x 16This

Page 21

DC Link Voltage [V]Variablename:SNVTtype: Value: nvoDCVoltage SNVT_volt Min. Max. Resolution: 0 V 10,000 V 0.1 VThis variable contains the measure

Page 22 - Danfoss FC Control Profile

Alarm FlagVariablename:SNVTtype:State: Value: Command:nvoAlarm SNVT_switch 0 (False) 0 No alarm(s) present 1 (True) 100 Alarm(s) presentThis variab

Page 23 - MG.11.BX.YY

1Copyright1.1 Copyright1.1.1 Copyright, Limitation of Liability and Revision Rights This publication contains information proprietary to Danfoss. By a

Page 24 - 42 Output Timeout Preset

Extended Status WordVariablename:SNVTtype:State:nvoExtendedStatusword SNVT_state_64 Boolean 1 bit x 64This variable contains the complete extended sta

Page 25 - X30/8 Output Timeout Preset

Analog Input (54)Variablename:SNVTtype: Value: nvoAnIn1 Changeable Min. Max. Resolution: SNVT_volt 0 V 10 V 0.1 VSNVT_amp_mil 0 mA 20 mA 0.1 mASNVT_l

Page 26 - Bypass Mode

Analog Input (X42/1)Variablename:SNVTtype: Value: nvo109AnIn1 Changeable Min. Max. Resolution: SNVT_volt 0 V 10 V 0.1 VSNVT_temp_p -273.15 °C 327.66

Page 27

ECB Option StatusVariablename:SNVTtype:State:nvoECBStatus SNVT_state Boolean 1 bit x 16This variable displays the current status of the ECB option.Bit

Page 28

5.3 VSD 6010 Profile5.3.1 IntroductionThe Variable Speed Drive 6010 profile is a LonMark standardized functional profile.It describes how to control a

Page 29 - Troubleshooting

5.3.4 Configuration Properties (nci)Variable function Variable name SNVT type ProfileFC 100 pa-rameterMax. motor speed [%] nciMaxSpeed SNVT_lev_percen

Page 30 - High Current

5.5 Network Variable Description - VSD Profile - Output5.5.1 Drive SpeedVariablename:SNVTtype: Value: nvoDrvSpeed SNVT_lev_percent Min: Max: Resolut

Page 31

5.6 Network Variable Description - VSD Profile - Configuration5.6.1 Max Motor Speed [%]Variablename:SNVTtype:Default value: Min value: Max value:nciMa

Page 32 - Analog I/O option, MCB109

5.6.5 Min Ramp-up Time [s]Variablename:SNVTtype:Default value: Min value: Max value:nciRampUpTime SNVT_time_sec 10 s 1 s 3,600 sThis variable configu

Page 33

5.7 Node Object5.7.1 Node ObjectThese variables are used for controlling all functional blocks via the com-missioning tool. 5.7.2 Object RequestVariab

Page 34 - 5.3 VSD 6010 Profile

2 Safety VLT® FC 100 LonWorks4MG.11.E2.02 - VLT® is a registered Danfoss trademark2

Page 35

5.8 Network Timer Functions5.8.1 Control Word Time-out Functionpar.8-03 Control Timeout Time and par.8-04 Control Timeout Function provide a means for

Page 36

6 How to control the Frequency Converter6.1 How to Control the FC 1006.1.1 Reference HandlingSelect the frequency converter configuration mode in par.

Page 37

6.2 Danfoss FC Control Profile6.2.1 FC Control ProfileControl Word According to FC Profile(Par. 8-10 set to FC Profile)Bit Bit value=0 Bit value=100 R

Page 38 - Ramp 1 Ramp Down Time

Bit 06, Ramp stop/start:Bit 06 set to [0] causes a stop, in which the motor speed is ramped downto stop via the selected ramp down parameter.Bit 06 se

Page 39 - 5.7 Node Object

6.2.4 Explanation of the Status BitsBit 00, Control not ready / ready:Bit 00 set to [0] means that the frequency converter has tripped.Bit 00 set to

Page 40 - 5.8 Network Timer Functions

7 How to access FC 100 parameters7.1 User-defined Network Variables UNVT7.1.1 UNVT Parameter structureTwo special User-defined Network Variables (UNVT

Page 41 - 6.1 How to Control the FC 100

7.1.2 UNVT examplesExample: Read parameter 3-41Ramp 1 Ramp-up TimeIn the LonMaker browser, select the nviParamRequest and choose [Details].130BA452.10

Page 42 - 6.2.1 FC Control Profile

In the bottom window, select the function [READ_VALUE].130BA451.10VLT® FC 100 LonWorks 7 How to access FC 100 parametersMG.11.E2.02 - VLT® is a regist

Page 43

In the [Field List:] under the section [par_number], enter the parameter number (in this example 3-41). If an indexed (array) parameter is accessed, t

Page 44

8 Parameters8.1 Parameter list8.1.1 Parameter listPar. No. Parameter name: Default value: Range:Conversiontype:Data type:8-01 Control Site Dig. and co

Page 45

2Safety2.1 Safety2.1.1 Safety noteThe voltage of the frequency converter is dangerous whenever connected to mains. Incorrect installation of the motor

Page 46 - 7.1.2 UNVT examples

[2] USB Port[3] * Option A[4] Option B[5] Option C0[6] Option C1NB!This parameter cannot be adjusted while the motor is running.8-03 Control Timeout

Page 47

8-05 End-of-Timeout FunctionOption: Function:Select the action after receiving a valid control word following a time-out. This parameter is activeonl

Page 48 - 130BA454.10

[1] Bus[2] Logic AND[3] * Logic ORNB!This parameter is active only when par.8-01 Control Site is set to [0] Digital and control word.8-52 DC Brake Se

Page 49 - 8 Parameters

NB!This parameter is active only when par.8-01 Control Site is set to [0] Digital and control word.8-55 Set-up SelectOption: Function:Select control

Page 50 - Option: Function:

8.3 Parameter Group 1111-00 Neuron IDRange: Function:View the Neuron chip's unique Neuron ID number.0 N/A* [0 - 0] View the Neuron chip's

Page 51

8.4 Data Types Supported by FC 1008.4.1 Object and Data Types Supported by FC 100Datatype:Description:3 Integer 164 Integer 325 Unsigned 86 Unsigned 1

Page 52

9 Troubleshooting VLT® FC 100 LonWorks56MG.11.E2.02 - VLT® is a registered Danfoss trademark9

Page 53 - 8-56 Preset Reference Select

9 Troubleshooting9.1 Alarm-, Warning and Extended Status Word9.1.1 Alarm and warning messagesGeneralThere is a clear distinction between alarms and wa

Page 54 - 8.3 Parameter Group 11

9.1.2 Alarm wordsAlarm word, par. 16-90 Alarm WordBit(Hex)Alarm Word(par. 16-90 Alarm Word)00000001 Brake check00000002 Power card over temperature000

Page 55 - 8.4.2 Conversion Index

9.1.3 Warning wordsWarning word , par. 16-92 Warning WordBit(Hex)Warning Word(par. 16-92 Warning Word)00000001 Brake check00000002 Power card over tem

Page 56

2.1.2 Safety Regulations1. The frequency converter must be disconnected from mains if repair work is to be carried out. Check that the mains supply ha

Page 57 - 9 Troubleshooting

9.2 Extended Status Word9.2.1 Extended status wordsExtended status word, par. 16-94 Ext. Status WordBit(Hex)Extended Status Word(par. 16-94 Ext. Statu

Page 58 - 9.1.2 Alarm words

9.3 Reference Scaling - Examples9.3.1 Reference Scaling - Open LoopExample:par. 3-02 Minimum Reference = 100 RPMpar. 3-03 Maximum Reference = 1500 RPM

Page 59 - 9.1.3 Warning words

9.4 Network Variables - Overview9.4.1 Output variables (nvo)Variable function Variable name SNVT type Profile FC 100par.Status word nvoStatusword SNVT

Page 60 - 9.2 Extended Status Word

9.4.2 Input variables (nvi)Variable Function Variable Name SNVT type Profile FC 100 par.Start/Stop nviStartStop SNVT_switch FC VSD CTW/referenceContro

Page 61 - Maximum Reference

IndexAAbbreviations 9About This Manual 7Alarm And Warning Messages 57Alarm Flag 29Alarm Word 58Alarm Word 29Analog Input (53) 30Analog Input (54) 31An

Page 62 - 9.4.1 Output variables (nvo)

Extended Status Word 30Extended Status Word 2 60FFanbelt Broken 28Fc Control Profile 42Fc Vsd Profile 20Fc Vsd Profile - Input 22Fieldbus Option 16Fre

Page 63 - 9.4.2 Input variables (nvi)

Output Variables (nvo) 62Output Voltage 36PParameter Access Command 26Parameter Access Response 33Parameter List 49Preset Reference Select 8-56 53QQue

Page 64 - Index VLT® FC 100 LonWorks

3Introduction3.1 Introduction3.1.1 About this manualFirst time users can obtain the most essential information for quick installation and set-up in th

Page 65 - VLT® FC 100 LonWorks Index

3.1.5 Background KnowledgeThe Danfoss LonWorks Option Card is designed to communicate with any system complying with the FTT and 78Kbps LonWorks stand

Page 66

3.1.8 AbbreviationsACK AC KnowledgeA AmpereBOOL BooleanCC Control CardCTW Control WordEMC Electromagnetic CompatibilityFTT Free Topology TransceiverHF