Installation
NB. For FRU units - go straight to point 6 below.
1. Loosen the  xing screw in the base of the unit to release the
Wiring Cover.
2. Holding the unit face downwards, press  rmly in the
centre of the wallplate and slide it apart and lift it from the
module.
3. Fix the wallplate and terminal block to the wall, or plaster
box, as required. Ensure that the screw heads do not
protrude beyond the vertical centre rib of the wallplate,
or this will prevent the module correctly locating onto the
wallplate.
4. Surface cables can only enter from below the unit. Cut
an appropriate cable aperture in the wiring cover. If the
wallplate is mounted on a plaster box, cables can enter
from the rear below the terminal block.
Installation
Screw  xing holes
(screwheads MUST
NOT protrude above
centre rib)
Vertical centre rib
Wallplate & Terminals