Technicaldata
VFBMC402
1
4
3
2
Main parts
1 Heat pump unit
• Scrollcompressor
• Stainlesssteelheatexchanger
• Circulationpumpsforbrineandheatingsystems
• Valvesandsafetyequipmentforcoolingsystemsandcorre-
spondingelectricalcomponents.
2 Water heater
• 180litres
• Internalanti-corrosionprotectionwithcopperorstainless
steel
• Ithasananodethatdoesnotrequirereplacing,whichmeans
thatitismaintenance-free
3 Exchange valve
• Theheatedwatereitherpassesthroughtotheheatingsys-
temortothewaterheaterdependingonwhetherheatingor
hotwateristobeproduced
4 Auxiliary heat
• 9kWelectricheatingelement(4.5kWat230Vheatpump
installation)
• Electricheatingelementcontrolinmaximumofthreesteps
• Installedontheheatingsystemssupplypipe
• Coversthedemandofextraenergyiftheheatpump’scapac-
ityisexceeded
• Automaticallyconnectedintheheatpumpunitifoperating
modeAUTOisselected.
5 Control equipment
• Controlcomputerwithgraphicdisplay
• Temperaturesensors(outdoor,supplypipe,returnpipe,brine
andhotwater)
• Roomsensor(option)
Thecontrolequipmentcontrolstheheatpupunit’sincludedcom-
ponents(compressor,circulationpumps,auxiliaryheatersand
exchangevalve)anddetermineswhentostartandstopthepump
aswellasproducingheatforthehouseorhotwater.