Connecting the inverters
Eaton
Solar-Log
1000/500/200
Installation 125 of 268
Connecting inverters to the Solar-Log
The wiring is done using the
ready-made data cable (optional extra; not supplied)
or
self-made, shielded 4 wire data cable and terminal block connector
( Page 15).

Note concerning Solar-Log
1000
:
Only connect inverter using the RS485/422 B interface.
Procedure
1 Open the inverter as described in the inverter instructions.
2 Pull the free wires through the wire opening in the inverter.
3 If you have made the cable connection yourself connect the wires as
shown in the following diagram:
Solar-Log™ terminal block connector
Inverter terminal strip
Terminal
Terminal
1
R+
4
R-
5
T+
6
T-
4 If only one inverter is to be connected terminate this in accordance with the
inverter instructions.
5 Close the inverter if no other inverters are to be connected.
6 Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a 4 wire, shielded data cable.
Where to connect: Terminal strip inside the inverter (on the retrofitted
RS485 interface)
Procedure
1 Open the inverter as described in the inverter instructions.
2 Connect terminals R+, R-, T+ and T- of inverter 1 to the corresponding
terminals on inverter 2.
3 Connect the other inverters to each other in the same way.
4 Terminate in the last inverter in accordance with the inverter instructions.
5 Close inverters.