Solar-Log500: Configuration at the unit
Configuring the inverter data (“Inverter” menu)
Solar-Log
1000/500/200
Installation 199 of 268
9.5.2 Inverter selection on RS485/422 B interface (Inverter/RS485/422)
Parallel operation of Bluetooth and RS485/422 is possible with SMA inverters.
1 In the menu, select Inverter/RS485/422
2 Select SMA as the inverter manufacturer
3 Press ENTER to save
If other inverters are to be configured, select the corresponding interface
and assign the inverter to it
4 To complete the inverter configuration, carry out the inverter detection
( Page 200)
9.5.3 Configuring the current meter on the S0 input (Inverter/S0 meter)
If an external S0 current meter is used, it must be activated here.
The S0 meter can be configured flexibly and used in 3 modes: as a current
meter for
an inverter.
In inverter mode, the meter can read an inverter for which the data pro-
tocol is not supported.
to meter the yield of the entire system
as a consumption meter.
1 In the menu, select Inverter/Bluetooth
2 Select a mode: Consumption, Inverter or Total yield
The pulse factor must then be set to match the pulse factor of the meter.
3 Enter the appropriate pulse factor
4 Press ENTER to save