Configuration at a PC
Solar-Log1000, 500: Re-detection after an inverter replacement (Basic/Inverter exchange)
160 of 268 Solar-Log
1000/500/200
Installation
8.7 Solar-Log
1000, 500
: Re-detection after an inverter replacement
(Basic/Inverter exchange)
In installations with numerous inverters, service cases occur from time to time
in which inverters need to be replaced. This can have effects on the Solar-
Log, which may need to be informed about the replacement. There are 2 cas-
es to be considered here:
Inverter with configurable address (e.g. Fronius, Kaco, Solarmax):
If the inverter address number can be configured directly on the display,
only the address of the old inverter must be assigned to the new inverter.
Inverter with fixed internal address (e.g. Fronius, Kaco, Solarmax):
In this case, the inverter that has been replaced must be configured in
Solar-Log. In particular, if more than 1 inverter is replaced, the re-
detection process is time-consuming. To alleviate the process, the In-
verter replacement function is integrated for all Solar-Log models
through a WEB interface.
Opening the dialogue box
On the navigation bar on the left, select Basic/Inverter exchange
The following dialogue box appears on the right:
To start inverter detection:
1 Click on the Start subsequent inverter identification button. The Solar-
Log™ starts looking for the detectors currently installed.
The search can last for some time, and the display appears as shown above.
The Solar-Logcompares the newly detected inverters with the list of exist-
ing inverters.