Danfoss TripleLynx CN Installation Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 268
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
Connecting the inverters
SMA
20 of 268 Solar-Log
1000/500/200
Installation
Connect inverters to the Solar-Log
The wiring is done using the
ready-made data cable (optional extra; not supplied)
or
self-made, shielded 4 wire data cable and terminal block connector
( Page 15).
Procedure
1 Pull the free wires through the wire opening in the inverter.
2 If you have made the cable connection yourself connect the wires as
shown in the following diagram:
Solar-Log™ terminal block connector
Inverter terminal strip
Terminal
Terminal
1
2
2
3
3
5
4
7
3 Pull the wire in the inverter through the insulation sleeve attached to the
piggy back.
The wire must be enclosed in the insulating hose inside the inverter.
4 Connect the earth: Connect terminal 5 of the inverter to the inverter hous-
ing using the supplied flatstrip connector.
5 If only one inverter is to be connected it must be terminated.
Attach the supplied jumper to the bottom pins on the connector strip:
Figure 11: Piggy back - insert jumper
6 Close the inverter if no other inverters are to be connected.
7 Insert the terminal block connector into the Solar-Log™ RS485 socket.
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 267 268

Comments to this Manuals

No comments