Connecting the inverters
Danfoss
Solar-Log
1000/500/200
Installation 37 of 268
Procedure
1 Unscrew the side cover as shown in the inverter's instructions.
2 If you are fabricating the cable yourself, connect the wires as shown in the
following diagram:
Solar-Log™ terminal block connector
RJ45 inverter
Terminal
Pin
1
6
3
1
3
2
4
3
CAUTION
Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to
the RJ45 socket on the inverter.
Only connect the inverter using the RS485/422 B interface of the
Solar-Log™ or on the Solar-Log
1000
also via the RS485 A interface.
3 If only one inverter is to be connected it must be terminated:
In the inverter insert the connection plug into the free RJ45 socket.
The connection plug is an 8 pin RJ45 dummy plug with bypassed wires:
Wires 3 and 4 bypassed and wires 5 and 6 bypassed.
4 Screw the inverter cover on again.
5 Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a network cable (patch cable)
Where to connect: 2 RJ45 sockets on the right on the side cover
Procedure
1 Unscrew the side cover as shown in the inverter's instructions.
2 Insert the RJ45 plug into any RJ45 socket on inverter 1.
3 Insert the other end of the wire into any RJ45 socket on inverter 2.
4 Connect the other inverters to each other in the same way.
5 Terminate in the last inverter:
Insert the connection plug into the free RJ45 socket.
6 Screw the inverter cover on again.