Connecting the inverters
Effekta
Solar-Log
1000/500/200
Installation 71 of 268
Connecting the inverters to each other (only Solar-Log
1000
)
Connection is made only with a ready-made data cable specially for
connecting the inverters to each other (optional extra: not supplied).
Where to connect: CAN socket outside the inverter
Procedure
1 Insert the CAN plug into any CAN OUT socket on inverter 1.
2 Insert the other end of the wire into any CAN IN socket on inverter 2.
3 Connect the other inverters to each other in the same way.
4 Terminate in the last inverter:
Insert the two 5 pin 120 Ω terminal resistors from the ready-made cable set
into the CAN OUT socket.
4.29 Effekta
Overview
Interface not integrated. Retrofit Effeckta RS485 interface.
3 pin wiring
Communication address must be allocated.
Work steps
• Switch off the inverters and the SolarLog™; Page 17
• Install the RS485 interface in the inverter
• Connect inverters to the Solar-Log™
• Connect the inverters to each other
• Allocate communication address
Installing the RS485 interface
Procedure
Install the RS485 interface in the inverter in accordance with the interface
card installation instructions.
Connect inverters to the Solar-Log™
The wiring is done using the
ready-made data cable (optional extra; not supplied)
or
self-made, shielded 3 wire data cable and terminal block connector
( Page 15).