Connecting the inverters
Effekta
Solar-Log
1000/500/200
Installation 71 of 268
Connecting the inverters to each other (only Solar-Log
1000
)
Connection is made only with a ready-made data cable specially for
connecting the inverters to each other (optional extra: not supplied).
Where to connect: CAN socket outside the inverter
Procedure
1 Insert the CAN plug into any CAN OUT socket on inverter 1.
2 Insert the other end of the wire into any CAN IN socket on inverter 2.
3 Connect the other inverters to each other in the same way.
4 Terminate in the last inverter:
Insert the two 5 pin 120 Ω terminal resistors from the ready-made cable set
into the CAN OUT socket.
4.29 Effekta
Overview
Interface not integrated. Retrofit Effeckta RS485 interface.
3 pin wiring
Communication address must be allocated.
Work steps
Switch off the inverters and the SolarLog™; Page 17
Install the RS485 interface in the inverter
Connect inverters to the Solar-Log
Connect the inverters to each other
Allocate communication address
Installing the RS485 interface
Procedure
Install the RS485 interface in the inverter in accordance with the interface
card installation instructions.
Connect inverters to the Solar-Log
The wiring is done using the
ready-made data cable (optional extra; not supplied)
or
self-made, shielded 3 wire data cable and terminal block connector
( Page 15).