Solar-Log1000: Configuration at the unit
Configuring the inverter data (Basic/Inverter)
230 of 268 Solar-Log
1000/500/200
Installation
Failure messages are always sent when the inverter is not working or not
online at times that have been configured as unshaded. It is then assumed
that there is a fault. Complete snow covering would therefore be reported
as a failure. To solve this problem, there is a checkbox for Permanent
snow covering. If the Yes box is ticked, no failure message is set if all in-
verters are offline. This option also depends on the current date. It is not
taken into account in the period from the start of November till the end of
April. Outside of this period, it is automatically disabled. Monitoring then
works as usual and also reports complete failures of all inverters.
Procedure
To set monitoring:
1 Touch Active
2 Touch the input boxes beside Unshadowed from and to
The virtual keyboard is opened.
3 Enter the desired period and confirm with OK
4 Touch the input box for Monitoring from minimum power.
The virtual keyboard is opened.
5 Enter the lower limit percentage of generator power at which monitoring is
to start, and confirm with OK
6 Where necessary: Enable Permanent snow cover possible.
7 Touch Save, then Next to go to the next dialogue.
Configure the message
Dialogue boxes
Message by
Alarm messages from the power monitoring can be sent by Email, SMS
and/or Relay.
Starting from a deviation of
If the target power deviates from the actual power by more than a certain
tolerance, a message can be sent by e-mail or SMS, or through a relay, af-
ter the selected fault duration.
Starting from malfunction duration of
This indicates how long a fault should be present continuously, before it is
recognised as a fault. The minimum duration is 5 minutes, but a longer one
should be selected.
Max. number of messages per day
A maximum number of messages per day can be defined so that any faults
occurring are not notified too often.