Solar-Log1000: Configuration at the unit
Performing the initial configuration (Config./Start/Initial configuration)
210 of 268 Solar-Log
1000/500/200
Installation
Procedure
1 Enter all the relevant data (see above list)
2 Touch Save, then Next to go to the next dialogue.
10.3.2 Inverter selection
In the inverter selection, manufacturers of the inverters connected to the
Solar-Log
1000
can be selected and assigned to all interfaces through a series
of dialogue boxes.
Inverter selection order:
– RS485-A
– RS485/422-B
Sensor (only with RS485-A and RS485/422-B):
The MT SensorBox is treated like an inverter and is therefore marked
as a MT&Sensor type (when selecting the inverters on RS485-A and
RS485/422-B).
– CAN
– Network
– S0
The inverter selection dialogue boxes are structured differently depending
on the interface.
Procedure
1 Touch Please choose
A list of inverters is displayed for selection:
2 Touch Select to select and assign an inverter
If no interface is assigned, select None
3 After each inverter selection, touch Save, then Next to go to the next dia-
logue.