Other connections
Large display (Solar-Log500, Solar-Log1000)
Solar-Log
1000/500/200
Installation 137 of 268
Connection through S0 output
If the S0 output is used, only the current feed-in power can be transmitted in
the form of a pulse sequence. The display has to calculate the power output
and total yield by itself.
Depending on the connector assignment in Solar-Log™, the S0 output can be
current-controlled or contact-controlled.
Wiring for a current-controlled S0 output
(Example: display system)
The wiring consists of a 2 pin shielded cable (2 x 0.6 mm²)
(up to 100 m long) and a terminal block connector ( Page 15).
Further information about connection can be obtained from the manufacturer
of the display.
Wiring for a contact-controlled S0 output
(Example: RiCo-Electronic)
The wiring consists of a 2 pin shielded cable (2 x 0.6 mm²)
(up to 100 m long) and a terminal block connector ( Page 15).
Terminal Solar-Log™ RS485-A/B
Further information about connection can be obtained from the manufacturer
of the display.
Pulse factor
In the standard setting, Solar-Log
1000
sends 1000 pulses/kWh over the S0 output.
The pulse factor must be configured according to the size of the installation (kWp):
Note that the pulse factor in the Solar-Log™ must have the same setting as
the connected device.