Configuration at a PC
Solar-Log1000, 500, 200: Configuring inverter data (Basic/Inverter)
166 of 268 Solar-Log
1000/500/200
Installation
If an individual module loses power, the string power for the same level of
irradiation will drop, and can thus be detected and reported.
Power comparison always works reliably even if the weather is cloudy.
The important thing is that all modules should not be overshadowed.
Therefore, the monitoring period should be scheduled for periods when
there are no shadows.
As power measurement in the inverter is very inaccurate under a certain
threshold, a minimum percentage value can also be specified below which
monitoring is interrupted.
Snowcover
False messages may occur if the unit is covered in snow. These are mes-
sages from the power comparison that occur if modules are partially cov-
ered, or failure messages if the inverter is no longer switched on because it
is fully covered by snow.
There are two ways to minimise this problem:
The minimum percentage value above which power monitoring starts
should be set as high as possible, e.g. 30%. For example, if the generator
power is 4500 Wp, power monitoring will start only at 1350 watts. The part-
ly shaded modules reduce the power from the unshaded modules so that
the required 1350 watts is never reached. This is how the problem of par-
tial covering is resolved.
Failure messages are always sent when the inverter is not working or not
online at times that have been configured as unshaded. It is then assumed
that there is a fault. Complete snow covering would therefore be reported
as a failure. In order to solve this problem there is an indicator for snow-
cover (Yes/ No). If this is set to Yes, no failure message is set if all invert-
ers are offline. This indicator also depends on the current date. It is not
taken into account in the period from the start of November till the end of
April. Outside of this period, it is automatically disabled. Monitoring then
works as usual and also reports complete failures of all inverters.
Period of malfunction
This indicates how long a fault should be present continuously, before it is
recognised as a fault. The minimum duration is 5 minutes, but a longer one
should be selected.
Maximum number of messages per day
A maximum number of messages per day can be defined so that any faults
occurring are not notified too often.
Activate required options and enter values.