Connecting the inverters
Europa-Solar AG (RS485)
Solar-Log
1000/500/200
Installation 75 of 268
5 Close the inverter if no other inverters are to be connected.
6 Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a 4 wire, shielded data cable.
Where to connect: Terminal strip inside the inverter on the retrofitted
RS485 interface card
Procedure
1 Open the inverter as described in the inverter instructions.
2 Connect terminals R+, T+, R- and R+ of inverter 1 to the corresponding
terminals on inverter 2.
3 Connect the other inverters to each other in the same way.
4 Terminate in the last inverter in accordance with the inverter instructions.
5 Close inverters.
4.31 Europa-Solar AG (RS485)
Overview
Interface integrated
Where to connect: RJ45 socket inside the inverter
4 pin connection only on RS485/422 B connection of the Solar-Log™
Communication address does not have to be allocated.

Note
The order in which the inverters are displayed in the Solar-Log™ after detection
is random. We strongly recommend that you change the order of the inverters
immediately after detection at startup, in the Configuration/Basic/Inverter
dialogue box (Page 162).
The inverters can be identified using the displayed serial number.
Work steps
Switch off the inverters and the SolarLog™; Page 17
Connect inverters to the Solar-Log
Connect the inverters to each other