Connecting the inverters
Siemens
Solar-Log
1000/500/200
Installation 111 of 268
Setting parameters
Parameters are set using the display on the inverter.
The date and time must be correctly set and the password 72555 en-
tered before the communication settings.
The communication parameters are set in the sub-menu
F1 -> Configuration -> Communication -> RS 485.
The individual menu items are selected with the arrow keys ↑↓ and
confirmed by pressing ENTER.
A consecutive communication address must be allocated to each
SINVERT PVM. It is advisable to arrange the addresses consecutively
beginning with 1, i.e. 1, 2, 3 up to a maximum of 31. The Solar-Log™
has address 0.
The baud rate can be selected freely but must be set to the same value
for all inverters. Baud rate 9600 must only be used when using the
wireless package.
How to set communication address parameters
1. Select USS address and press ENTER.
2. Enter the numerical value xx [Address] and press ENTER.
3. Select Baud rate and press ENTER.
4. Enter the numerical value [Baud rate] and press ENTER.
5. Select Protocol and press ENTER.
6. Select protocol type 1 and press ENTER.
After the parameters have been set on the display the inverter must be
switched off for one minute using the installed DC isolation switch. The set-
tings are now applied and set to active. The configuration procedure is de-
scribed in the manufacturer's handbook. From Solar-Log firmware version
2.0.3 (Nov.09) no other parameters must be set on the inverter. Commission-
ing can be continued immediately.
Solar-Log™ compatibility with older PV installations
With older Solar-Log™/PVM installations the inverter had to be set with additional
parameters for Solar-Log™ compatibility. This is only still necessary if an inverter
has been replaced because it was faulty or if the system has been extended. Only
in these cases must the additional parameters be set again on the new inverters.