Connecting the inverters
Carlo Gavazzi
116 of 268 Solar-Log
1000/500/200
Installation
Procedure
Open the inverter as shown in the inverter's instructions.
1. If your have made the cable yourself, connect the wires as shown in
the following diagram:
Solar-Log™ terminal block connector
2. Insert the RJ1plug into any RJ11 socket on inverter 1.
3. Close the inverter if no other inverters are to be connected.
4. Insert the terminal block connector into the SolarLog™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Wiring using the RJ11 cable
Where to connect: RJ11 sockets
Procedure
1. Open the inverter as shown in the inverter's instructions.
2. Insert the self-made cable with the RJ11 plug into any RJ11 socket on
inverter 1. Connect the other end to the terminal plug on the Solar-Log™
3. Insert the cable into the 2nd RJ11 socket on inverter 1 and into any
RJ11 socket on inverter 2. inverter 2.
4. Connect the other inverters to each other in the same way.
5. Insert the terminal block connector into the SolarLog™ RS485 socket.
6. Close inverters.
4.56 Carlo Gavazzi
Overview
Interface integrated
Where to connect: RJ45 socket on the outside of the inverter
2 pin wiring
Communication address must be allocated.