Connecting the inverters
Danfoss
36 of 268 Solar-Log
1000/500/200
Installation
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a network cable (patch cable)
Where to connect: RJ45 socket on the outside of the inverter
Procedure
1 Insert the RJ45 plug in inverter 1 into the OUT socket.
2 Insert the other end of the wire into the IN socket on inverter 2.
3 Connect the other inverters to each other in the same way.
4 Terminate in the last inverter:
Insert the supplied connection plug into the RJ45 OUT socket.
5 Close inverters.
Allocating communication address
Recommendation: Continuous numbering starting with 1.
Setting: Using the inverter operating display
Procedure: As set out in the inverter's instructions
4.9 Danfoss
Overview
Units by the following manufacturers supported: Danfoss, UniLynx and
TripleLynx
UniLynx types: Interface integrated from 02/2007
TripleLynx types: Interface integrated
Where to connect: 2 RJ45 sockets on the right on the side cover
Communication address does not have to be allocated.
4 pin wiring
Work steps
Switch off the inverters and the SolarLog™; Page 17
Connect inverters to the Solar-Log
Connect the inverters to each other
Connecting inverters to the Solar-Log
The wiring is done using the
ready-made RJ45 data cable (optional extra; not supplied)
or
your own fabricated cable connection with RJ45 plug and terminal
block connector ( Page 15)