Solar-Log500: Configuration at the unit
Configuring the inverter data (“Inverter” menu)
200 of 268 Solar-Log
1000/500/200
Installation
9.5.4 Run the inverter detection (Inverter/Detection)
Inverter detection can be started here. To be detected, the inverters must be
feeding in.
1 Select Inverter/ Detection/Yes from the menu.
Provided they have been activated, the individual interfaces of the Solar-
Log
500
are queried in order:
Bluetooth:
First, all SMA Bluetooth interfaces are shown in a list. Since more in-
verters may be detected than are actually installed (e.g. those in a
neighbouring house may also be detected), the listed inverters have to
be checked.
RS485/422
S0 meter
The meter must send at least 1 pulse within 60 seconds.
During detection, the inverters that have been detected are displayed im-
mediately. Detection can take some time. Channel lists are loaded for
SMA inverters. This can take several minutes for each inverter.
After inverter detection, the total number of inverters detected is displayed.
2 Delete Bluetooth inverters from the list.
Select inverters and press ENTER
If the selection is correct: Press ESC.
Inverter detection can be repeated at any time, or cancelled completely.
Re-detection of inverters
If new inverters have been added to the system or, for example, SMA invert-
ers have been replaced, it will also be necessary to carry out a new detection
process ( Page 160). This will not cause any loss of data, as Solar-Log
500
au-
tomatically re-formats the data. However, before running a new detection,
it is essential to make a data backup at the PC and restore the backup af-
terwards if necessary.