Connecting the inverters
Aten
Solar-Log
1000/500/200
Installation 121 of 268
Connecting inverters to the Solar Log
They are wired using the:
self-made, shielded 2 wire data cable and terminal block connector
(Page 15).
Procedure
1. If your have made the cable yourself, connect the wires as shown in the
following diagram:
Solar-Log™ terminal block connector
Inverter
RS485/422 B
RJ 14 socket
1
Pin 2 Data +
4
Pin 4 Data -
RJ14 socket pin allocation
2. Close the inverter if no other inverters are to be connected.
3. Insert the terminal block connector into the SolarLog™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a 2 wire, shielded data cable.
Where to connect: RJ14 sockets
Procedure
1. Open the inverter as shown in the inverter's instructions.
2. Insert the self-made cable with the RJ14 plug into any RJ14 socket on inverter 1.
3. Insert the cable into the 2nd RJ11 socket on inverter 1 and the RJ14 socket on
inverter 2.
4. Connect the other inverters to each other in the same way.
5. Close inverters.
6. Insert the terminal block connector into the SolarLog™ RS485 socket.